Specifications

ISF.png

InSight Face

Performance

Capture Volume Nominal 1.0-2.5m depth
Capture volume configurable by software and hardware options
Capture Volume height 0.9 – 2.2m
Based on 1.55 m standard device mounting height
Matching time 1 second or less when used with Tascent-ES, subject to network latency

Capture_Volumes.pngFunctional

User Interface


Integrated high resolution 10.1 “ LCD, 1280x800px (portrait)

Fully configurable multi-color front LED ring
Fully configurable multi-color rear LED indicator

Power Line voltage: 100 – 240VAC Frequency: 50/60 Hz
Power supply: 90W (24 VDC at 3.75A)
Weight 3.5 kg (7.6 lbs) without mounting hardware
System Interface

Network connection: Gigabit Ethernet,

USB 2.0 for maintenance operation

HDMI - InSight Face Plus only

Mounting options

Floor mount (to eGate, fixed position counters),

VESA mount,

Desktop stand.

Dimensions H x W x D 370mm x 180 mm x 100mm

Biometric

Face Capture Sensor

InSight Face Plus: Two 2.3MP CMOS Image Sensors; On-board high-performance ISP

InSight Face Standard: Single 2.3MP CMOS Image Sensors;

Lenses

InSight Face Plus: Left 2.8 mm Right 5.5 mm

InSight Face Standard: Left only : selectable 2.8mm or 5.5 mm;

Face Tracking / Capture

Continuous – 30fps / Two modes of operation:

Single Face
Multi Face

Ambient Lighting environment 300 - 10,000 lux

ISF___EBT_front.png

InSight Face  + EBT

Elevated Body Temperature

Telethermographic System

Temperature Uncertainty

< ±0.5°C (±0.9°F) over the temperature range of at least 34-39°C

(93.2-102.2°F)

Precision (Temperature stability between calibrations) <0.2°C (0.36°F)
Noise Equivalent Temperature Difference (NETD) <50mK @30°C
Target Pixel Sampling @2m < 2mm / Pixel
Subject height range 4’6” to 6’4” (extended height range for ADA compliance is available as an option)
Approval FDA 510K
Deployment

Includes a separate black-body temperature reference source

Available as a retrofit for existing InSight Face systems

 

Was this article helpful?
0 out of 0 found this helpful